Sizes | DN 3 … 100 (1/10 … 4") | DN 1 … 100 (1/25 … 4") | DN 1 ... DN 100 1/25 ... 4 in. |
Accuracy | 0,4% of rate, Option: 0,2% of rate |
0,3% of rate, Option: 0,2% of rate |
0.5 % of rate |
Communication | HART-Protocol (Standard) Profibus PA, FOUNDATION Fieldbus |
HART-Protocol (Standard) Profibus PA, FOUNDATION Fieldbus |
HART, PROFIBUS PA, FOUNDATION Fieldbus |
Special features |
Flowmeter with Standard Functionality. Processdiagnosis: Empty Pipe Detection. Verification through Softwaretool „ScanMaster“ |
Flowmeter with enhanced functions and options such as: Diagnostic: Detection of Empty Pipe, gasbubbles, electrode coating Monitoring of: Conductivity, Sensor temperature, good Grounding Verification through Softwaretool „ScanMaster“ |
Difficult applications |
<="" a="" style="border-bottom-width: 1px; border-bottom-style: dotted; border-bottom-color: rgb(51, 51, 51); color: rgb(51, 51, 51); padding-bottom: 1px; text-decoration: none;"> | ![]() |
![]() |
FES7000 (Fill-MAG) | FXF2000 (COPA-XF) |
![]() |
>>read more | >>read more |
![]() |
||
Sizes | DN 1 ... DN 100 1/25 ... 4 in. |
DN 3 ... DN 100 1/8 ... 4 in. |
Accuracy | 1 % of rate Repr. 0.2 % |
0.5 % of rate Repr. 0.2 % |
Special features |
Intelligent filling system |
For continuous and batch applications |
<="" a="" style="border-bottom-width: 1px; border-bottom-style: dotted; border-bottom-color: rgb(51, 51, 51); color: rgb(51, 51, 51); padding-bottom: 1px; text-decoration: none;"> | ![]() |
![]() |
ProcessMaster 300 | ProcessMaster 500 |
![]() |
>>>read more | >>>read more |
![]() |
||
Sizes | DN 3 … 2000 (1/10 … 80") | DN 3 … 2000 (1/10 … 80") |
Accuracy | 0,4% of rate Option: 0,2% of rate |
0,3% of rate Option: 0,2% of rate |
Communication | HART-Protocol (Standard) Profibus PA, FOUNDATION Fieldbus |
HART-Protocol (Standard) Profibus PA, FOUNDATION Fieldbus |
Special features |
Flowmeter with Standard Functionality. Processdiagnosis: Empty Pipe and partially filling detection. Verification through Softwaretool „ScanMaster“ |
Flowmeter with enhanced functions and options such as: Diagnostic: Detection of Empty Pipe, partially filling, gasbubbles, electrode coating Monitoring of: Conductivity, Sensor temperature, good Grounding Verification through Softwaretool „ScanMaster“ |
<="" a="" style="border-bottom-width: 1px; border-bottom-style: dotted; border-bottom-color: rgb(51, 51, 51); color: rgb(51, 51, 51); padding-bottom: 1px; text-decoration: none;"> | Go to table 2 |
![]() |
WaterMaster | AquaMaster | AquaProbe |
![]() |
>>read more | read more | >>read more |
![]() |
|||
Sizes | DN 40 ... DN 2200 1-1/2 ... 90 in. |
DN 15 ... DN 600 1/2 ... 24 in. |
DN 200 ... DN 8000 8 ... 320 in. |
Accuracy | 0.2 % OIML R49, 0.4 % (standard) |
CEN Pr EN 14154 Compliant | 2 % of rate |
Communication | HART PROFIBUS DP |
![]() |
HART, PROFIBUS DP |
Special features |
![]() |
Water Network Management | Flow probe |
<="" a="" style="border-bottom-width: 1px; border-bottom-style: dotted; border-bottom-color: rgb(51, 51, 51); color: rgb(51, 51, 51); padding-bottom: 1px; text-decoration: none;"> | Go to table 3 |
![]() |
FXP4000 (PARTI-MAG II) |
![]() |
>>read more |
![]() |
|
Sizes | DN 150 ... DN 2000 6 ... 80 in. |
Accuracy | 1 % of rate with full pipe 3 % of rate with partially filled pipe |
Communication | ![]() |
Special features | Partially filled pipes |
<="" a="" style="border-bottom-width: 1px; border-bottom-style: dotted; border-bottom-color: rgb(51, 51, 51); color: rgb(51, 51, 51); padding-bottom: 1px; text-decoration: none;"> |
![]() |
MagMaster | MagMaster Loflo | CalMaster and VeriMaster |
![]() |
>>read more | >>read more | >>read more |
![]() |
![]() |
>>read more | |
![]() |
|||
Sizes | DN 10 ... DN 50 3/8 ... 2 in. |
||
Accuracy | 3 % of rate 1.5 % (option) |